632 Treffer

632 Treffer für alle Seiten auf der gesamten Webseite

Formulas and definitions.pdf

APPENDIX FORMULAS AND DEFINITIONS Rating Voltage Current Resistance The following formulas and definitions apply to all applications: DEFINITION: Resistivity, ρ Ωmm2/m (Ω/cmf) The resistance of a conductor, R20, is directly propor- tional to its length, L and inversely proportional to its

Design calculations for heating elements_examples.pdf

APPENDIX EXAMPLES Tubular element for a flat iron Rating, P 1,000 W Voltage, U 220 V Final tube diameter 8 mm (0.315 in) Final tube length 300 mm (11.8 in) If the terminal length inside the tube is 2 × 25 mm the coil length (Le) will be Le = 300 mm – (2 × 25 mm) = 250 mm (9.8 in). Hot

Gehe zu Seite:Zurück, 1, , 58, 59, 60, 61, 62, 63, 64(Diese Seite)